准直多孔掩膜成像系统的高精度标定方法

    High-precision calibration method for collimated porous mask imaging system

    • 摘要: 基于准直光入射的多孔掩膜成像系统可在有限像面尺寸下实现大视场覆盖,但其标定面临全局模型难以表征各孔位的局部误差特征、逐孔模型又约束不足的两难困境。为此,提出一种标定方法:首先基于标定数据,以全局最小二乘优化估计掩膜-像面间距、安装姿态角及像面参考中心等全局几何参数;随后将标定数据按孔位分组,逐孔建立三次多项式误差补偿模型,补偿孔位局部误差;最后依据各孔模型残差确定置信度,对各孔解算的入射光线投影角实施自适应加权融合。实验结果表明,该方法的入射光线投影角测量精度可达6.1″/6.8″(3σ),实现了角秒级高精度测量。

       

      Abstract: A large field of view can be covered by a porous mask imaging system based on collimated light incidence under a limited image plane size, but its calibration is faced with a dilemma in which global geometric errors are difficult to be characterized by a global model for each hole position, while sufficient constraints cannot be provided by a per-hole model. To address this issue, a calibration method was proposed. First, based on calibration data, global geometric parameters, including the mask-to-image-plane spacing, the mounting attitude angles, and the image-plane reference center, were estimated by global least-squares optimization. Subsequently, the calibration data were grouped according to hole positions, and a cubic polynomial error compensation model was established for each hole so that local errors of the hole positions could be compensated. Finally, confidence levels were determined according to the residuals of each hole model, and adaptive weighted fusion was performed on the projection angles of the incident rays solved for each hole. Experimental results show that a measurement accuracy of 6.1″/6.8″ (3σ) is achieved for the projection angle of the incident rays by this method, by which high-precision measurement at the arcsecond level is realized.

       

    /